| << Previous Page | Supermount 1000 Series | |||||||||
| Contact Us | ||||||||||
![]() |
Supermount 1000 Series The Supermount 1000 series is a versatile low profile mount that serves a wide variety of process control and vessel weighing applications in most types of industries. Capacities range from 1000 lbs. to 200,000 lbs. The Supermount 1000 series anchors directly to the floor or structural support. Its self-contained design eliminates the need for check rods, stops or stay rods. 5 Year Warranty |
FEATURES
|
APPLICATIONS
|
OPTIONS
|
DURABLE
|
SPECIFICATION

| The best positioning of 1000 Series mount assemblies is shown above in diagram 1-4. The mounts should be positioned with the long axis of the load cell at a right angle to the line drawn. The long axis of the load cell should point in line with any recurring force. Such as a Conveyor or Tank Scale. This will allow the least restricted vessel movement and allow for thermal expansion and contraction. |
OUTLINE DRAWINGS

1000 SERIES DIMENSIONS:
MODEL NUMBER |
CAPACITY |
W1 |
W2 |
L1 |
L2 |
S1 |
S2 |
J |
H |
T |
1000-1-5 |
1K-5K |
5.00 |
3.75 |
9.25 |
6.25 |
4.00 |
2.75 |
.50 |
5.13 |
.56 |
1000-1-5-SS |
||||||||||
1000-10-35 |
10K-35K |
8.00 |
6.00 |
12.00 |
7.50 |
8.00 |
6.00 |
.75 |
7.90 |
.78 |
1000-10-35-SS |
||||||||||
1000-50-75 |
50K-75K |
12.00 |
9.50 |
16.25 |
11.50 |
9.00 |
6.50 |
1.00 |
9.30 |
.78 |
1000-50-75-SS |
INCELL uses Non-proprietary load
cells in all of its mounts. The following is a list of
load cells that can be used with the 1000 Series mounts :
Other load cells may also be available. |